Skip to content
Home » LOITHIUM PHOSPHATE SMART BMS

LOITHIUM PHOSPHATE SMART BMS

Lithium Phosphate Smart BMS

Products Menu

BMS
Lithium ion
Hardwere BMS
Softwere BMS (Smart BMS)

Lithium phosphate
Hardwere BMS
Softwere BMS (Smart BMS)

TECHNICAL DETAILS:

  • Single cell voltage detection range 1.5V-4.6V. 
  • High precision detection cell voltage error is less than 5MA 
  • Charging current 50A 
  • Discharge current: 120-160A Continuous 320 Peak (Depending on which BMS model you buy) 
  • Balance current :200MA. 
  • Controlled balance mode, when you start charging, the voltage difference can be detected by the voltage difference greater than the set value. 
  • High-precision coulomb counter function temperature control detection Hall speed measurement 
  • Bluetooth connection: support for android with Bluetooth 4.0 
  • Support cells: Support Li-ion, Lipo, 18650, Lifepo4, LTO and so on 
  • Voltage accuracy: Single cell voltage detection range (1.5-4.6V), accuracy error within 3 mV 
  • Overcharge protection 
  • Over discharge protection 
  • Short circuit protection: Up to 320A 
  • Overcurrent protection: maximum 300A 
  • Current detection: within the current range of the BMS 
  • Temperature control protection: The protection board has built-in balanced temperature control, power temperature, and can be connected with 4 temperature sensors to prevent high temperature danger

TECHNICAL PARAMETERS:

16 SERIES, 40A/60A/100A



No.

Test item

Criterion

1

Voltage

Charging voltage

DC:60V 3.6V/Cell

Balance voltage for single cell

3.60±0.025V

2

Current

Balance current for single cell

72±10mA

Current consumption

≤20μA

Maximal continuous charging current

40A/60A/100A

Maximal continuous Discharging current

40A/60A/100A

3

Over charge Protection

Over charge detection voltage for single cell

3.90V±0.025V

Over charge detection delay time

0.5S—2S

Over charge release voltage for single cell

3.80V±0.05V

4

Over discharge protection

Over discharge detection voltage for single cell

2.30V±0.08V

Over discharge detection delay time

10mS—200mS

Over discharge release voltage for single cell

2.70V±0.10V

5

Over current protection

Over current detection voltage

150mv±25mv

Over current detection current

150A ±20A

Detection delay time

5mS—15mS

Release condition

Cut load

6

Short protection

Detection condition

Exterior short circuit

Detection delay time

200-500us

Release condition

Cut load

7

Resistance

Protection circuitry(MOSFET)

≤20mΩ

8

Temperature

Operating Temperature Range

-40~+85℃

Storage Temperature Range

-40~+125℃

20 SERIES, 40A/60A/100A

 

 

No.

Test item

Criterion

1

Voltage

Charging voltage

DC:72V 3.6V/Cell

Balance voltage for single cell

3.60±0.025V

2

Current

Balance current for single cell

72±10mA

Current consumption

≤20μA

Maximal continuous charging current

40A/60A/100A

Maximal continuous Discharging current

40A/60A/100A

3

Over charge Protection

Over charge detection voltage for single cell

3.90V±0.025V

Over charge detection delay time

0.5S—2S

Over charge release voltage for single cell

3.80V±0.05V

4

Over discharge protection

Over discharge detection voltage for single cell

2.30V±0.08V

Over discharge detection delay time

10mS—200mS

Over discharge release voltage for single cell

2.70V±0.10V

5

Over current protection

Over current detection voltage

150mv±25mv

Over current detection current

150A ±20A

Detection delay time

5mS—15mS

Release condition

Cut load

6

Short protection

Detection condition

Exterior short circuit

Detection delay time

200-500us

Release condition

Cut load

7

Resistance

Protection circuitry(MOSFET)

≤20mΩ

8

Temperature

Operating Temperature Range

-40~+85℃

Storage Temperature Range

-40~+125℃

24 SERIES, 40A/60A/100A

 

 

No.

Test item

Criterion

 

1

 

Voltage

Charging voltage

DC:86V 3.6V/Cell

Balance voltage for single cell

3.60±0.025V

2

Current

Balance current for single cell

72±10mA

Current consumption

≤20μA

Maximal continuous charging current

40A/60A/100A

Maximal continuous Discharging current

40A/60A/100A

 

3

 

Over charge Protection

Over charge detection voltage for single cell

3.90V±0.025V

Over charge detection delay time

0.5S—2S

Over charge release voltage for single cell

3.80V±0.05V

 

4

 

Over discharge protection

Over discharge detection voltage for single cell

2.30V±0.08V

Over discharge detection delay time

10mS—200mS

Over discharge release voltage for single cell

2.70V±0.10V

5

Over current protection

Over current detection voltage

150mv±25mv

Over current detection current

150A ±20A

Detection delay time

5mS—15mS

Release condition

Cut load

 

6

 

Short protection

Detection condition

Exterior short circuit

Detection delay time

200-500us

Release condition

Cut load

7

Resistance

Protection circuitry(MOSFET)

≤20mΩ

 

8

 

Temperature

Operating Temperature Range

-40~+85℃

Storage Temperature Range

-40~+125℃

 

Let's Save Energy Together