PRODUCT INTRODUCTION:

      This charge-discharge test equipment is mainly used for lithium battery charge-discharge cycle test, the test items include: battery charge protection voltage, discharge protection voltage, capacity, etc. The device has four test steps: charging, discharging, shelving, and cycling. By editing the corresponding steps, the battery can be tested in accordance with the set process.        

TECHNICAL PARAMETERS:

1. Material name

Battery Pack 100V 20A Charging & Discharging Aging Tester

2、Channels information

1. Channels quantity

Channels quantity in

one unit

8

2. Main channel

Channel feature

Constant current source and constant voltage source dual closed loop control

Channel control

mode

Independent control

Channel parallel connection

Support max 4 channels parallel mode. Pulse and SIM tests will be disabled in channels parallel mode.

3、Power grid side parameters

1.Input power

 

AC380V±15% 50/60±5Hz

2.Power factor

 

≥99% (Full load)

3.THDi

 

≤5% (Full load)

4.Input resistance

 

≥1MΩ

5.Input power

 

18.8KW

6.Input current

 

28.6A/single

7.Overall system

efficiency (Max)

 

90%

8.Noise

 

65dB

9.Voltage and current sampling

 

Four-wire connection (same port for charging and discharging)

10.Power control module

type

 

MOSFET

11.Input power wiring

method

 

Three-phase-five wire system

12.Power input protection

 

Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti-phase absence, etc.

4、Functions and performances

1. Voltage

Output range

Charge:0V100V

Discharge:3V100V

 

Min discharge

voltage

3V

Accuracy

±0.02% of FS

Resolution

24bit

2. Current

Output range

0.1A20A

Accuracy (independent

not range)

±0.1% of FS

CV cut-off current

30mA

Resolution

24bit

3. Power

Single channel

output power

2KW

Whole machine output power

16KW

   

4. Time

Current response

time

3ms

Current conversion

time

6ms

Min. step time

0.1s

5. Charge/Discharge modes

Charge/Discharge modes

CCC, CVC, CC-CVC, CPC

CCD, CVD, CPD, CRD

Cut-off condition

Voltage, Current, Time, Capacity, -ΔV

6. Simulation

Charge

Current, Power

Discharge

Current, Power

Switch

Support continuous switching between charge and

discharge

Cut-off condition

Time, step line

Steps file lines

1,000,000

7. Pulse Mode

Charge

Current, power

Discharge

Current, Power

Min pulse

100ms

Pulse counts

Up to 32

Charge and

discharge switch

supported

Cut-off condition

Voltage, Time

8. DCIR

 

DCIR by calculation

9. Safely protection

Software protection

Power off data protection

Offline mode function

Safety protection conditions can be set, including: voltage lower limit, voltage upper

limit, current lower limit, current upper limit, delay

time, etc.

Hardware protection

Anti-reverse connection, over-voltage, over-current,

over-temperature, etc.

5、Data management and analysis

1. Step setting method

 

Form editing

2. Data report

Recording conditions

Minimum time interval: 10ms (connected with AUX

channel:100ms

Minimum voltage interval: 0.2V

Minimum current interval: 0.04A

Recording frequency

100Hz (connected with AUX channel:10Hz)

3. Database

 

MySQL database

4. Data output

 

Excel, Txt

5. Curve type

 

Templates available, customization supported

6. Bar code scanning

 

Support bar-code scanning function

Management and traceability of historical data

6、Communication

1. Host computer communication

 

TCP/IP protocol

2. Communication port

 

Ethernet

3. Communication baud rate of the testers

 

1M

4. Host computer

communication baud rate

 

10M~100M adaptive

5. Communication setup

 

Set up a LAN (local area network) through switches

and routers

6. Communication expansion(optional)

 

Support CAN, RS485 communication and BMS communication, with DBC configuration function

7、Environmental requirements, dimension and weight

1. Operation environment temperature

 

-10℃~40℃ (When the temperature is 25±10℃, the

accuracy error caused by temperature change is less than 0.005% of FS per degree)

2. Storage environment

temperature

 

-20℃~50℃

3. Operation environment humidity

 

≤70% RH (no moisture condensation)

4. Storage environment

humidity

 

≤80% RH (no moisture condensation)

5. Dimension W*D*H

 

600*800*1300(mm)

6. Weight

 

about 178.4KG

7. Tester Picture (Pictures

 