TECHNICAL DETAILS:

  • Single cell voltage detection range 1.5V-4.6V. 
  • High precision detection cell voltage error is less than 5MA 
  • Charging current 50A 
  • Discharge current: 120-160A Continuous 320 Peak (Depending on which BMS model you buy) 
  • Balance current :200MA. 
  • Controlled balance mode, when you start charging, the voltage difference can be detected by the voltage difference greater than the set value. 
  • High-precision coulomb counter function temperature control detection Hall speed measurement 
  • Bluetooth connection: support for android with Bluetooth 4.0 
  • Support cells: Support Li-ion, Lipo, 18650, Lifepo4, LTO and so on 
  • Voltage accuracy: Single cell voltage detection range (1.5-4.6V), accuracy error within 3 mV 
  • Overcharge protection 
  • Over discharge protection 
  • Short circuit protection: Up to 320A 
  • Overcurrent protection: maximum 300A 
  • Current detection: within the current range of the BMS 
  • Temperature control protection: The protection board has built-in balanced temperature control, power temperature, and can be connected with 4 temperature sensors to prevent high temperature danger

TECHNICAL PARAMETERS:

16 SERIES, 40A/60A/100A



No.

Test item

Criterion

1

Voltage

Charging voltage

DC:60V 3.6V/Cell

Balance voltage for single cell

3.60±0.025V

2

Current

Balance current for single cell

72±10mA

Current consumption

≤20μA

Maximal continuous charging current

40A/60A/100A

Maximal continuous Discharging current

40A/60A/100A

3

Over charge Protection

Over charge detection voltage for single cell

3.90V±0.025V

Over charge detection delay time

0.5S—2S

Over charge release voltage for single cell

3.80V±0.05V

4

Over discharge protection

Over discharge detection voltage for single cell

2.30V±0.08V

Over discharge detection delay time

10mS—200mS

Over discharge release voltage for single cell

2.70V±0.10V

5

Over current protection

Over current detection voltage

150mv±25mv

Over current detection current

150A ±20A

Detection delay time

5mS—15mS

Release condition

Cut load

6

Short protection

Detection condition

Exterior short circuit

Detection delay time

200-500us

Release condition

Cut load

7

Resistance

Protection circuitry(MOSFET)

≤20mΩ

8

Temperature

Operating Temperature Range

-40~+85℃

Storage Temperature Range

-40~+125℃

20 SERIES, 40A/60A/100A

 

 

No.

Test item

Criterion

1

Voltage

Charging voltage

DC:72V 3.6V/Cell

Balance voltage for single cell

3.60±0.025V

2

Current

Balance current for single cell

72±10mA

Current consumption

≤20μA

Maximal continuous charging current

40A/60A/100A

Maximal continuous Discharging current

40A/60A/100A

3

Over charge Protection

Over charge detection voltage for single cell

3.90V±0.025V

Over charge detection delay time

0.5S—2S

Over charge release voltage for single cell

3.80V±0.05V

4

Over discharge protection

Over discharge detection voltage for single cell

2.30V±0.08V

Over discharge detection delay time

10mS—200mS

Over discharge release voltage for single cell

2.70V±0.10V

5

Over current protection

Over current detection voltage

150mv±25mv

Over current detection current

150A ±20A

Detection delay time

5mS—15mS

Release condition

Cut load

6

Short protection

Detection condition

Exterior short circuit

Detection delay time

200-500us

Release condition

Cut load

7

Resistance

Protection circuitry(MOSFET)

≤20mΩ

8

Temperature

Operating Temperature Range

-40~+85℃

Storage Temperature Range

-40~+125℃

24 SERIES, 40A/60A/100A

 

 

No.

Test item

Criterion

 

1

 

Voltage

Charging voltage

DC:86V 3.6V/Cell

Balance voltage for single cell

3.60±0.025V

2

Current

Balance current for single cell

72±10mA

Current consumption

≤20μA

Maximal continuous charging current

40A/60A/100A

Maximal continuous Discharging current

40A/60A/100A

 

3

 

Over charge Protection

Over charge detection voltage for single cell

3.90V±0.025V

Over charge detection delay time

0.5S—2S

Over charge release voltage for single cell

3.80V±0.05V

 

4

 

Over discharge protection

Over discharge detection voltage for single cell

2.30V±0.08V

Over discharge detection delay time

10mS—200mS

Over discharge release voltage for single cell

2.70V±0.10V

5

Over current protection

Over current detection voltage

150mv±25mv

Over current detection current

150A ±20A

Detection delay time

5mS—15mS

Release condition

Cut load

 

6

 

Short protection

Detection condition

Exterior short circuit

Detection delay time

200-500us

Release condition

Cut load

7

Resistance

Protection circuitry(MOSFET)

≤20mΩ

 

8

 

Temperature

Operating Temperature Range

-40~+85℃

Storage Temperature Range

-40~+125℃

 